--- On Wed, 3/20/13, elggobo wrote:

From: elggobo
Subject: [CWSG] Re: SK1 to Vent Wiring diagram.
To: CloneWheel@yahoogroups.com
Date: Wednesday, March 20, 2013, 5:06 AM

 

The idea of keeping audio ground and switching ground separate has been used on Leslie connections for a long time. The idea is that switching transients caused for example by back-EMF from relays (a pulse of current when the relay coil is turned off) don't make their way through to the audio channel as clicks and pops. Also if a less regulated PSU is used for the switching channel you could also get 50/60Hz hum this way as well.

Try to get the SK1 schematic and find out which ground is which and use them appropriately.

--- In CloneWheel@yahoogroups.com, "thefinalg" wrote:
> Or, maybe the "audio ground" and the leslie "ground" are separated so that the leslie speed control (which switches tip-ground to ring-ground) is removed/insulated from the audio-side connection. I.e., as you're switching the leslie speed you are connecting and disconnecting things to ground, and by having a separate "audio ground" pin you have a constant, unaffected ground to the audio signal.